Build Guide - Calibration

The calibration process determines the minimum frequency at which the ED722 will operate.

  1. Set the [RATE] control to minimum
  2. Set P4 to its centre position
  3. Fit jumper JP1 in to the 'CAL' position
  4. Monitor the [TRI-SAW] output using a multimeter
  5. The output will exhibit a tendency to drift positive or negative and the voltage will eventually settle at +12V or -12V
  6. Reset the output voltage by momentarily shorting JP2
  7. Adjust P4 until the voltage remains stable with minimal drift for a period of several seconds
  8. Repeat steps (6) and (7) until the drift is only a few millivolts over several seconds
  9. Fit JP1 in to the 'RUN' position and ensure JP2 is open