Set the [RATE] control to minimum
-
Set P4 to its centre position
-
Fit jumper JP1 in to the 'CAL' position
-
Monitor the [TRI-SAW] output using a multimeter
-
The output will exhibit a tendency to drift positive or negative and the voltage will eventually settle at +12V or -12V
-
Reset the output voltage by momentarily shorting JP2
-
Adjust P4 until the voltage remains stable with minimal drift for a period of several seconds
-
Repeat steps (6) and (7) until the drift is only a few millivolts over several seconds
-
Fit JP1 in to the 'RUN' position and ensure JP2 is open