Build Guide - Calibration

The PREAMP and DETECTOR cirucits do not require any calibration.

The following steps adjuste the points at which the PEAK and ENVELOPE LEVEL indicators operate.

PEAK Indicator (CLIPPING)

  1. Patch a 440Hz 200mVAC sine wave into [Hi-Z IN].
  2. Monitor [PREAMP OUT] and adjust [GAIN] for a level of 5.5VAC
  3. Set P1 fully counter-clockwise
  4. Adjust P1 until the LED just turns OFF

ENVELOPE LEVEL

You will need an envelope generate and a VCA with logarithmic control input to generate an amplitude modulated signal.

  1. Set the envelope generator to output a fast rising 4Hz 5VDC sawtooth
  2. Patch the sawtooth into the LOG input of the VCA
  3. Patch a 2kHz 5VAC sine wave into the AC input of a VCA
  4. Patch the VCA output into the [IN] input of the Detector
  5. Set the [COUPLE] switch off (up)
  6. On a dual trace scope display the [ENVELOPE] output and the original sawtooth. Note that both of these displays are of CVs and are not audio
  7. Now, while monitoring the scope, adjust the VCA's gain control knob so that the two traces look almost exactly alike

Adjust P1 so that intensity of the LED follows the [ENVELOPE] output and is extinguished when the envelope is close to zero

 

 

 

 

 

 

 

 