Build Guide - Calibration
  1. Set mode to [XY]
  2. Monitor [OUT] with a DMM
  3. Adjust P201 for 0V output
  4. Apply +6VDC to [VC-X] and [VC-Y]
  5. Adjust P101 for an output of 6VDC
  6. Remove the +6VDC
  7. Monitor [OUT] with an oscilloscope
  8. Patch a 100Hz 5VAC triangle to [X]
  9. Adjust P102 for minimum AC feedthrough
  10. Move the patch from [X] to [Y]
  11. Adjust P201 for minimum AC feedthrough