Build Guide - Calibration |
|
- Set all controls to minimum
- Patch [SMOOTH CYCLE] to [SMOOTH IN]
- Monitor [SMOOTH OUT]
- Adjust P301 for 1.6kHz
- Patch [STEPPED CYCLE] to [STEPPED IN]
- Monitor [STEPPED OUT]
- Set P401 fully clockwise
- Adjust P401 until the frequency just starts to drop (typically you should be able to adjust for an output frequency of ~500Hz)
- Install R409
Functional Test
- Patch [SMOOTH CYCLE] to [SMOOTH IN]
- Patch a 10Hz 5VDC square wave signal to [HOLD]
- Monitor [SMOOTH OUT]
- Confirm that [SMOOTH OUT] is being cycled ON and OFF
- Patch [STEPPED CYCLE] to [STEPPED IN]
- Set [STEPPED RATE] to about '3'
- Patch a 10Hz 5VDC square wave signal to [SAMPLE]
- Confirm that [STEPPED OUT] is generating STEPPED voltages
- Adjusting [STEPPED RATE] up and down should result in the size and number of steps increasing and decreasing
|
|
|
|
|
|
|