Build Guide - Calibration |
|
- Set [GAIN] to maximum
- Set P101 to its mid-point
- Set P201 fully counter-clockwise
- Connect +3VDC to [LOG] and [DC IN]
- Adjust P103 until +6VDC is measured at [OUT]
- Disconnect +3VDC from [LOG]
- Adjust P101 until +3VDC is measured at [OUT]
- Repeat steps (4) to (7) for best results
- Disconnect +3VDC from [DC IN]
- Connect sawtooth to [LIN]
- Adjust P201for minimum amplitude at [OUT]
|
|
|
|
|
|