If fitted, set [INITIAL GAIN] to 0V
(fully CCW).
Set P2 and P3 to their mid-positions.
1. Connect a10Hz 5VDC triangle signal to [VC 1]
2. Set [GAIN] to maximum
3. Monitor [OUT] with a scope in the 100mV
range(*)
4. Adjust P3 (OFFSET) to set any DC offset close
to 0V
5. Adjust P2 (CV REJECT) to reduce any
breakthrough to minim
6. Repeat steps (4) and (5) until an optimum
result is achieved
7. Connect a 440Hz 5VAC triangle to [IN 1]
8. Connect a 5VDC signal to [VC 1]
9. Adjust P1 (CV INIT) until the output is 5VAC.
|