Set [RESONANCE] and
[FREQUENCY] to maximum
-
Set P1 to its
mid-position
-
Monitor the wiper of
P4 and adjust it for 0.0V
-
Set P2 to its
mid-position
-
Monitor [OUT] which
should be oscillating. If not, back off
the [FREQUENCY] control slowly until it
does
-
Set [RESONANCE] to
'8'
-
Adjust P2 (normally
this will be a clockwise rotation) until
the oscillations stop
-
Set [RESONANCE] to
maximum, the oscillations should restart
-
Repeat steps (6) to
(8) if needed
-
Set [FREQUENCY] to
its mid-position
-
Adjust P4 for a
frequency of approximately 200Hz