Build
Guide - Calibration
|
|
- Connect 0.0VDC to [CV IN]
- Connect a 1Hz 5VDC squarewave
to [CLOCK]
- Wait for about 5 seconds
- Monitor TP1 and adjust P201
for a reading of 0.0V
- Monitor TP2 and adjust P202
for a reading of 0.0V
- Monitor TP3 and adjust P203
for a reading of 0.0V
- Connect 5.0VDC to [CV IN]
- Wait about 5 seconds
- Monitor [OUT 1] and adjust
P205 for 5.0VDC
- Monitor [OUT 2] and adjust
P206 for 5.0VDC
- Monitor [OUT 3] and adjust
P207 for 5.0VDC.
|
|
|
| |
|
|
|
|